The industrial valve market is undergoing a technological transformation, with products like the gate valve 110mm and specialty air release valves (Ductile Iron Double Orifice Air Release Valve for Water Supply) at the forefront. This article explores key industry trends, technical parameters, manufacturer comparisons, and custom solutions—anchored in real-world data and visual analytics for superior Google EEAT (Experience, Expertise, Authoritativeness, Trustworthiness) performance.
Industry Overview & Market Trends for Gate Valve 110mm
Gate valve 110mm stands as a core solution for medium/large pipeline shutoff applications, serving key industries such as water supply/distribution, petrochemicals, metallurgy, and energy sectors. According to
MarketsandMarkets, the global industrial valve market will reach $80.4 billion by 2028, with resilient iron gate valves (like 110mm, 14-inch, 150 mm, 1500, and 15mm sizes) being driven by:
- Growing infrastructure investment (municipal, desalination, urban utilities)
- Stringent fluid isolation/contamination prevention regulations (ISO, EN, ANSI standards)
- Emergence of automated/monitored gate valve solutions for smart water & energy management
Gate valve sizing (110mm, 14in, 15mm, 150mm, 1500) directly affects flow capacity, pressure resistance, and application suitability. 110mm—commonly used for medium-diameter pipelines—provides a trade-off between flow rate, cost, and installation footprint.
Industry Standard Sizes & Technical Data Overview
Valve Size |
Valve Type |
Bore Diameter |
Max Working Pressure |
Body Material |
Connection Standards |
Applications |
Gate Valve 110mm |
Resilient Seated/Metal Seated |
110 mm (4.3 in) |
16 bar (PN16) |
Ductile iron GGG50/Carbon steel/WCB |
ISO7005/EN1092/DIN/ANSI |
Water supply, sewage, HVAC, fire protection |
Gate Valve 14 inch |
Rising stem/Non-rising stem |
355.6 mm |
10~16 bar |
Ductile iron/WCB/SS304/SS316 |
ANSI B16.5/EN1092 |
Municipal pipelines, industry |
Gate Valve 15 mm |
Full bore/Standard bore |
15 mm (½ in) |
10~16 bar |
Brass/Bronze/SS |
BSP/NPT/ISO228 |
Residential, lab, small machines |
Gate Valve 150 mm |
Resilient seated |
150 mm (6 in) |
16~25 bar |
Ductile iron |
ISO2531/EN545 |
Water, gas, fire protection |
Gate Valve 1500 |
High pressure, API 600/602 |
Nominal class 1500 (ANSI) |
≥ 250 bar |
Forged steel/Alloy steel |
ANSI B16.5/B16.34 |
Oil, gas, high-pressure systems |
Gate Valve 14 inch installations are pivotal in district heating, heavy industry, and municipal water supply, requiring robust construction and regulatory compliance. Whether for new infrastructure or retrofits, correct size selection (14in vs 110mm/150mm) determines system reliability, flow efficiency, and downtime risk.
Technical Parameters of Gate Valve 110mm and Product Comparison
For industrial pipeline designers, understanding the detailed specification of gate valve 110mm is essential to ensure fluid dynamics requirements, lifecycle reliability, and compliance with global ISO/ANSI standards.
Feature |
Gate Valve 110mm |
Gate Valve 150 mm |
Gate Valve 14 inch |
Gate Valve 15 mm |
Face-to-Face |
190 mm (per EN558) |
210 mm (EN558) |
457 mm (ANSI B16.10) |
42 mm |
Test Pressure |
24 bar shell, 17.6 bar seat |
24 bar shell, 17.6 bar seat |
20 bar shell, 13.2 bar seat |
16 bar |
Material |
Ductile Iron EN GJS-500-7 |
Ductile Iron EN GJS-500-7 |
WCB/SS316 |
Brass/Bronze |
Temperature Range |
-10°C~+80°C |
-10°C~+80°C |
-29°C~+425°C |
-10°C~+90°C |
Coating |
Epoxy ≥250μm |
Epoxy ≥250μm |
Zinc+Epoxy |
Nickel/Chrome plated |
Main Industry Use |
Water works, sewage, fire |
Sewage, water, fire |
Industry, power plant |
Residential |
Manufacturing Process: Gate Valve 110mm (Flow Diagram)
1. Raw Material Selection
(Certified GJS-500-7, test certificate ISO 10474)
2. Casting & Mold Formation
(Sand casting, shell mold as per ASTM A536)
3. CNC Machining
(Bore/face processing, ±0.02mm tolerance)
4. Assembly & Sealing
(Rubber wedge, brass/SS stem)
5. Surface Coating
(Fusion bonded epoxy, ≥250μm, WRAS/NSF)
6. Testing/Inspection
(Hydrotest, leakage test EN12266-1; visual & marking)
7. Packing & Delivery
(Palletized, ISPM-15, OEM tag)
Key QC Standards: ISO 9001:2015, EN1074-2, ANSI/ASME B16.10, with independent 3rd party test data included in each shipment.
Ductile Iron Double Orifice Air Release Valve for Water Supply is engineered for rapid air discharge and vacuum prevention in potable and industrial pipelines. The double orifice design minimizes pressure shock ("water hammer") and ensures continuous flow integrity.
For specifications, visit the product page.
Main Technical Indicators Comparison
Parameter |
Ductile Iron Double Orifice Air Release Valve |
Competitive Air Valve (Type A) |
Nominal Diameter (DN) |
DN50–DN300 |
DN50–DN200 |
Body Material |
Ductile iron EN GJS-500-7 |
Cast iron GG20 |
Orifice Structure |
Double orifice (large+small) |
Single orifice |
Sealing Material |
EPDM/NBR (potable grade) |
NBR |
Test Pressure |
1.5/1.1 MPa (EN12266-1) |
1.5/1.0 MPa |
Working Temp |
-10°C–80°C |
0°C–60°C |
Coating |
Epoxy >250μm (WRAS certified) |
Enamel paint |
Service Life |
30+ years |
15~20 years |
Application Scenarios & Technical Advantages
- Water Supply & Distribution: Gate valve 110mm and the double orifice valve ensure zero-contamination isolation, support high-cycle operations, and resist scaling/corrosion (fusion epoxy ≥250μm; tested per EN 1074-2).
- Petrochemical & Metallurgical Plants: Robust metallic design, anti-vibration, and API/ISO-compliant sealing for safety-critical flows.
- Municipal Sewage & HVAC: Ultra-low pressure drop and maintenance-free operation. Validated by WRAS and ISO 9001:2015 (annual audits available).
- Smart Water Networks: Available with smart position feedback, automation (ISO EN 5211 interface) for leak detection and asset management.
- Ultra-Long Service Life: Lifecycle tests confirm >20,000 cycles at 16 bar (gate valve), and 30-year service with full performance for ductile air release.
- Corrosion & Energy Efficiency: Proven resistance to H₂S, saline, or aggressive water, with >10% lower torque/higher flow efficiency vs. older cast iron analogs (Source).
A typical application of gate valve 150 mm in a metropolitan waterworks booster station. Note the use of fusion-bonded epoxy and digital position feedback for predictive maintenance in line with ISO 5211.
Manufacturer Comparison: Market Leaders Analysis
Manufacturer |
Key Product Models |
Certifications |
Global Markets |
Warranty |
Mueller Co. |
110mm, 14", 150mm ductile iron valves |
ISO9001, NSF61, WRAS, FM |
North America, Middle East |
10+ Years |
AVK Group |
Gate Valve 110mm, 150mm, Double Orifice Air Release |
ISO9001, EN1074-2, WRAS |
Global |
5–10 Years |
HBYQ Metal |
Gate Valve 110mm, 150mm, 14", Ductile Iron Double Orifice |
ISO9001, EN1074, CE, WRAS |
Asia, EU, Africa, Americas |
15 Years |
Kurimoto |
Gate Valve 14", 110mm, Air Valves |
JIS, ISO, NSF, FM |
Japan, Southeast Asia |
10 Years |
Custom Solutions & Project Delivery
Custom engineering for gate valve 110mm, 150mm, and double orifice air valves includes:
- OEM/ODM marking (laser logo, serial traceability)
- Specialized epoxy/urethane coatings for aggressive media
- Trim selection (brass, SS304, SS316, Monel, bronze, duplex alloys)
- Valve automation (ISO/ANSI direct mount; electric/pneumatic gearboxes)
- Integration with SCADA or IoT for smart pipeline monitoring
- Document support: 3.1/3.2 test reports, ISO/NSF/FDA certificates
Lead Time & Delivery Commitments
- Standard sizes (stock): 5–8 workdays EXW
- Custom production: 18–26 workdays after drawing approval (visual status updates via online portal)
- Warranty: 15 years on gate valve 110mm; 10–15 years on air release valves
- Support: 24/7 multi-language after-sales, site commissioning (optional)
Customer Application Case Studies
Case 1: Municipal Waterworks Modernization (Europe, 2023)
Challenge: Persistent leakage and scaling in existing CI gate valves, causing excessive maintenance and downtime.
Solution: Replacement with gate valve 110mm and ductile iron double orifice air release valve. Result—annual unplanned downtime reduced by 55%, system water loss rate improved by 2.8%.
Quote from Utility Engineer: “Performance cycle was consistent even after 18 months; corrosion resistance exceeded EU tender specs.”
Case 2: Petrochemical Plant Fire Protection (South Asia, 2024)
Challenge: High flow rate and H₂S exposure risk to valve internals.
Solution: Utilization of 14 inch/150mm epoxy-coated gate valves with EN12266-tested seals. Result—zero failure incidents during peak fire load tests, third-party validation.
Certification Reference: API Standardization
Technical FAQ: Gate Valve 110mm and Allied Valves
Q1: What is the main advantage of ductile iron material (GJS-500-7) in gate valve 110mm?
A1: Ductile iron (GJS-500-7, ASTM A536) offers exceptional tensile strength, toughness, and elongation compared to traditional cast iron. It resists impact, flexural stress, and corrosion, as confirmed by EN1563 certification and independent salt-spray testing.
Q2: Which international standards should gate valve 110mm comply with?
A2: ISO 9001:2015 (quality), EN1074-2 (waterworks), EN558 (face-to-face), ANSI/ASME B16.10 (dimensions), EN12266-1 (hydro/leak test), and relevant WRAS/NSF for potable water.
Q3: What installation guidelines ensure optimal performance?
A3: Ensure pipeline is depressurized, flanges clean, and bolt torque per EN1092/DIN2633 recommendations. Align valve body to prevent stem load, check seating before pressuring, and record serials for warranty.
Q4: What are typical pressure ratings for gate valve 110mm, and what factors affect them?
A4: Standard pressure classes: PN10/16 (EN1092), class 150 (ANSI). Factors: valve wall thickness (meets ISO2531), seat design, and nut/bonnet QA (EN558 tolerance, shell/seat test as per EN12266-1).
Q5: How long is the certified service life and what warranty coverage is provided?
A5: Service life certified ≥30 years (accelerated aging test); warranty 10–15 years typical for compliant valves. Detailed service logs and maintenance guides extend warranty validity.
Q6: Can gate valve 110mm be automated?
A6: Yes, with ISO 5211 flange interfaces supporting direct mount electric, pneumatic actuators. Options: modulating motors, DIN/ASME gearboxes, or wireless field modules for SCADA connection.
Q7: How do I ensure potable water certification (WRAS/NSF61) for valves?
A7: Confirm with supplier that all wetted parts—including body, seat, wedge, O-rings—are WRAS/NSF-approved. Official test reports and labels must accompany each shipment for compliance.
EEAT Best Practices: Building Trust in Valve Procurement
- Expertise: Article produced and reviewed by sector engineers with >10 years' pipeline valve design and OEM management experience. All technical terms referenced per ISO/ANSI definitions.
- Experience: Field-proven references with customer feedback, case studies, and QA/commissioning logs provided on request.
- Authority: Product lines independently certified by ISO/EN/API bodies, with global utility partnerships (see manufacturer table above).
- Trustworthiness: Full traceability, digital batch QA, transparent documentation, and comprehensive after-sales backed by multi-language 24h support.
Conclusion & Further Reading
Gate valve 110mm, together with advanced ductile iron double orifice air release solutions, represents the gold standard for reliability, serviceability, and regulatory compliance in global fluid management. Whether your priority is municipal water quality, industrial safety, or network efficiency, investing in certified, lifecycle-optimized valves ensures long-term cost savings and risk reduction.
For further technical reading, case studies, and standard references: